Sterlco SDA Series Medium Capacity Dehumidifying Dryer User Manual

Page 44

Advertising
background image

Cabinet Series Dehumidifying Dryer

44

Level 1 AL-2 Alarm Value 2

-1999 to 9999 EU

0

25.0

Level 1 AL-3 Alarm Value 3

-1999 to 9999 EU

0

Default

Level 1 P Proportional Band

0.1 to 999.9% FS

10.0

4.4

Level 1 I Integral Time

0 to 3999 SEC

233

84

Level 1 d Derivative Timer

0 to 3999 SEC

40

13

Level 1 C-SC Cooling

Coefficient

0.01 to 99.99

1.00

Default

Level 1 C-db Dead Band

-19.99 to 99.99%FS

0.00

Default

Level 1 6F-r Manual Reset

Value

0.0 to 100.0%

50.0

Default

Level 1 HYS Hysteresis (Heat)

0.01 to 99.99%FS

0.10

Default

Level 1 CHYS Hysteresis (Cool) 0.01 to 99.99%FS

0.10

Default

Level 1 CP Control Period

(Heat)

1 to 99 SEC

20

Default

Level 1 C-CP Control Period

(Cool)

1 to 99 SEC

20

Default

Mode Parameter

Setting

range

Default

Factory

setting

Level 2 r-L Remote/Local

RMT/LCL

LCL

Default

Level 2 SPrU Sp Ramp Time Unit

M(Minutes)/H(Hours)

M

Default

Level 2 SPrE Sp Ramp Set Value

0 to 9999 EU

0

Default

Level 2 LbA LBA Detection Time

0 to 9999 SEC

0

Default

Level 2 Au-5 MV at Stop

-5.0 to 105.0%

0.0

Default

Level 2 Au-E MV at PV Error

-5.0 to 105.0%

0.0

Default

Level 2 6L-L MV Upper Limit

MV Lower Limit +0.1 to 105.0%

105.0

Default

Level 2 6L-L MV Lower Limit

-5.0 to MV Upper Limit –0.1%

-5.0

Default

Level 2 6rL MV Change Rate Limit 0.0 to 100.0%/SEC

0.0

Default

Level 2 CnF Input Digital Filter

0 to 9999 SEC

0

Default

Level 2 ALH1 Alarm 1 Hysteresis

0.01 to 99.99%

0.02

Default

Level 2 ALH2 Alarm 2 Hysteresis

0.01 to 99.99%

0.02

Default

Level 2 ALH3 Alarm 3 Hysteresis

0.01 to 99.99%

0.02

Default

Level 2 Cn5H Input Shift Upper

Limit

-199.9 to 999.9

°C

0.0 Default

Level 2 Cn5L Input Shift Lower

Limit

-999.9 to 999.9

°C

0.0 Default

Mode Parameter

Setting

range

Default

Factory

setting

Setup Cn-E Input Type

0 to 21

2

3

Setup

Cn-H Scaling Upper

Limit

Scaling Lower Limit +1 to 9999 EU

-100

Default

Setup

Cn-L Scaling Lower

Limit

-1999 to SP Setting Upper Limit -0.1 EU

0

Default

Setup dP Decimal Point

0 to 3

0

Default

Setup d-U

°C/F Selection

°C/F

°C

°F

Setup CnCE

Parameter

Yes/No

No

Default