Sterlco SDD Series User Manual

Page 71

Advertising
background image

882.01749.00

71

of

93

4-3 Removing the “DD” Disc and Cleaning the Dosing Module

Dismantling the Dosing Module

1. Switch the control unit “Off” with

the “On/Off” switch.

2. Disconnect the power supply.

3. Open the toggle latches on the

dosing motor.

4. Remove the dosing unit from

the dosing motor.

5. Empty the dosing module.

6. Open the profile clamp on the

dosing hopper.

7. Remove the dosing hopper from the dosing module.

8. Dismantle the dosing module and remove the shear (D) as described above in 5.2.

9. Loosen and remove the two M6 x 30 socket screws (C) on top of the dosing disc (A).

10. Remove the center M6 x 12 socket screw (B) and replace with an M6 x 30 or 60 screw.

11. Lift the dosing disc (A) from the

dosing unit housing (B) by

tightening this screw.

12. Clean the shear plate with a

cotton cloth.

13. Clean the dosing hopper and the

dosing disc in soapy water.

14. The dosing unit housing may also

be cleaned with a soft cloth,

keeping liquids out of the

bearings.