“DT” Pellet & Regrind Discs

“DP” Powder Discs



Additive Sample weighing.

Weighing samples of additive provides for more precise control of feed rate. Up to 5

samples can be weighed. All weights entered are averaged to arrive at a value to be used

during operation. The weighing process may be skipped altogether, in which case the

calibration weight is used for calculations of feed rate. See the section Weight Calibration at

the end of this section.

Feeder Configuration – Simple extrusion:

Touch the ACS logo on the main menu screen to access the configuration menu. See section # for
details.


Feeder Type Selection. Select simple extrusion.

Disc

Thickness

Disc

Calibration

Number

No. of

Pockets

10 mm

DT 30-101820

32.00

20

DT 30-102025

(“Sure-shot” - 20

oval holes)

38.00

20 Oval

20mm

DT 30-203012

100.00

12

DT 30-204010

175.00

10

Disc

Calibration

Number

Disc

Thickness

DP 30-

050940

17.00

5mm

DP 30-

250940

8.00

2.5mm