Sterlco SDD Series User Manual

Page 77

Advertising
background image

77 of 96

4-4 Removing/Replacing the Wiper in the “DT” Dosing Station

1. Switch the control unit “Off” with the “On/Off” switch.

2. Disconnect the power supply.

3. Empty the dosing station.
4. Open the toggle latches on the dosing
motor.
5. Remove the dosing unit from the
dosing motor.
6. Open the profile clamp (C) of the dosing

container.

7. Remove the profile clamp (C).
8. Remove the dosing module
(A and B).
9. Loosen the 3 plastic screws on
the wiper.
10. Remove the wiper and holding plate.
11. Install the new wiper along with the holding plate.
12. Tighten down the 3 plastic screws. Make sure that the wiper is fitted parallel to

the dosing plate (Use only plastic screws to avoid damage to the extruder or

molding machine screw should the mounting screws ever come loose.)
13. Install the dosing hopper on the dosing housing, ensuring the guide pin is in place,
and locate the “shelf” above the module discharge hole.
14. Install and tighten the profile clamp.








Advertising