Sterlco SDD Series User Manual

Page 67

Advertising
background image

67 of 96

LED Yellow (Station)

on: Station Filled

off: Station Emptied

LED Green (Level Probe)

on: Power Supply Available

off: Power Supply Not Available

Trim-pot with

Plastic Screw M3

Cable

Blind Lid

Protective Screw

npn: Normally Closed

pnp: Normally Open

1

0

npn: Normally Open

pnp: Normally Closed

Level Probe

Figure 7. Level Sensor Adjustment Screw

4. Turn the trim-pot until the yellow control lamp just switches off.

NOTE: Turning the trim-pot to the left decreases the switching sensitivity, and

turning it to the right increases the sensitivity.

5. Fill the dosing station until the level probe is two-thirds covered. The yellow control

lamp should now switch on again. If not, repeat Step 4.

6. Reinstall the plastic screw (M3).

NOTE: The sliding switch under the cover must be set on “0”.

Communication Protocol Interfaces
The Digital Dosing feeder can be controlled remotely through ODBUS RTU protocol. Contact the
Sales Department at 810.720.7300 for more information.

OPTIONAL Additive Hoppers
Various styles of additive hoppers and options are also available for the Digital Dosing feeder.
Contact the Sales Department at 810.720.7300 for more information.