Canon VB-M600VE User Manual

Page 145

Advertising
background image

List of Log Messages

8

-15

8

A

ppendix

S412 Timer service initialization error [crit]

S413 Timer service runtime error [crit]

S501 Fan stop detected [alert] (VB-M600VE)

S502 Temperature fuse disconnect detected [alert]

(VB-M600VE)

Description

timer initialization error [%1] [%2] (S412)

%1

Error number

%2

Cause of error

Meaning

An error occurred in the initialization of the
timer service.

Countermeasure

If the problem persists after rebooting, the
camera is faulty. Arrange for servicing.

Description

timer working error [%1] (S413)

%1

Error number

Meaning

An error occurred while the timer service
was running.

Countermeasure

If the problem persists after rebooting, the
camera is faulty. Arrange for servicing.

Description

FAN rotation speed is less than 150rpm.
(S501)

Meaning

The camera's internal fan has stopped or
RPM has dropped significantly.

Countermeasure

Camera needs to be serviced.

Description

Heater unit error. Fuse is cut off. (S502)

Meaning

The temperature fuse on the heater
substrate was disconnected.

Countermeasure

Camera needs to be serviced.

Advertising
This manual is related to the following products: