Electrolux EP19WI30LS User Manual

Page 10

Advertising
background image



Description

Ref

A=

Clearance above grade, veranda, porch, deck, or balcony

B=

Clearance to window or door that may be opened

C=

Clearance to permanently closed window

D=

Vertical clearance to ventilated soffit located above the
terminal within a horizontal distance of 2 feet (61 cm)
from the center line of the terminal

E=

Clearance to unventilated soffit

F=

Clearance to outside corner

G=

Clearance to inside corner

H=

Clearance to each side of center line extended above
meter/regulator assembly

I=

Clearance to service regulator vent outlet

J=

Clearance to nonmechanical air supply inlet to building or
the combustion air inlet to any other appliance

K=

Clearance to a mechanical air supply inlet

L=

Clearance above paved sidewalk or paved driveway located
on public property

Clearance under veranda, porch, deck, or balcony

M=

1

In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code

* Clearance in accordance with local installation codes and the requirements of the gas supplier.

b

Clearance to opposite wall is 24 inches (60 cm).

12 in (30 cm)

*

*

*

*

*

*

*

*

3 ft (91 cm) above if within

10 ft (3 m) horizontally

*

12 in (30 cm)

12 in (30 cm)

US Direct Vent Installations

1

Vent Terminal

D

E

B

B

F

B

A

G

H

I

C

B

M

K

J

B

B

L

Air Supply Inlet

Area Where Terminal
is Not Permitted

A

Clearance Requirements from Vent Terminations to Building Openings
<When supplying combustion air from the outdoors (Direct Vent)>

"MMDMFBSBODFSFRVJSFNFOUTBSFJOBDDPSEBODFXJUI"/4*;BOEUIF/BUJPOBM'VFM(BT$PEF 

"/4*;