Quick connect multi system installation, Typical plumbing, System diagram – Electrolux EP19WI30LS User Manual

Page 5

Advertising
background image

3

G

Quick Connect
Cord

Remote Controller Cord

Gas Supply Piping

Cold Water Supply

Hot Water

Remote Controller

Terminal Block

Cord
Connector

Cord
Connector

3.

Quick Connect Multi System Installation

r5IF2VJDL$POOFDU.VMUJ4ZTUFNBMMPXTUIFJOTUBMMBUJPOPGUXPVOJUTUPHFUIFSVUJMJ[JOHPOMZUIF2VJDL

Connect Cord.

Typical Plumbing

* When connecting two units, use only a

single remote controller.

Note: Connect the remote

controller to only one
of the units.

System Diagram

r*OTVMBUF UIF IPU XBUFS QJQJOH UP QSFWFOU IFBU MPTT *OTVMBUF BOE BQQMZ IFBUJOH NBUFSJBMT UP

the cold water supply piping to prevent heat loss and freezing of pipes when exposed to
excessively cold temperatures.

Union

Make this distance as short
as possible.
* The hot water temperature
will become unstable as the
pipe length increases.

Distance at center: 20.3 - 36.3 in. (515 - 922mm)

Quick Connect Cord

Union

Gas Valve

Union

Shutoff Valve

Shutoff Valve

Hot Water

Shutoff Valve

Cold Water

Distance on sides

2 - 18 in. (50 - 457mm)

Leave enough clearance around the plumbing to
apply insulation. It will be necessary to add
bends to the piping to ensure that this clearance
is available.

Size the piping to allow for the
maximum flow rates of the units.

The backflow preventer is
put up before it diverges.

Pressure
Relief Valve

5IF2VJDL$POOFDU$PSEJTGU N MPOH*OTUBMMUIFVOJUT NN BQBSUGSPNFBDI
other to ensure the cord will be able to reach between the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach,
but the water temperature may also become unstable because of the difference in pipe length
between the two units).