Slope pipe downwards
1/4" per foot.

The end of the drain pipe
must have an air gap.

The end of the drain pipe
must have an air gap.

Condensate piping to floor drain

Slope pipe downwards
1/4" per foot.

1/2" PVC pipe

1/2" PVC elbow

3/8" ID tubing*

* Install tubing according to pump
manufacturer's instructions.

Condensate piping with pump

Condensate pump

Floor drain

MAINTAIN CLEARANCE

1/2" PVC pipe

DO NOT ADD
ANY VALVES

Electrolux

Condensing

Tankless Gas
Water Heater

DO NOT ADD
ANY VALVES

Electrolux

Condensing

Tankless Gas
Water Heater

/PUF
If the drain line becomes clogged or frozen, condensate will back-up into the water heater and a "29"
error code will flash on the remote controller, ceasing operation. If this occurs, clear the clog or freeze
so that condensate can freely flow. Be sure to slope the drain pipe, use the appropriate size pipe, allow
the proper clearances, and apply freeze prevention measures (when necessary) to prevent the drain
line from clogging or freezing.