Caution – Electrolux EP19WI30LS User Manual

Page 25

Advertising
background image

23

Table 3. Maximum Undiluted Propane (LP) Delivery Capacity in Thousands of
BtuH (0.5” WC Pressure Drop) [Schedule 40 Metalic Pipe]

For reference only. Please consult gas pipe manufacturer for actual pipe capacities.

Final Check
When the installation is complete, verify that inlet gas pressure for the entire gas system does not
drop below 5” WC for NG or 8” WC for LP at all appliances. This can be tested by turning on all
gas burning appliances including the water heater, then check the inlet pressure at each appliance
to verify all appliances are receiving a minimum of 5” WC for NG or 8” WC for LP. If all appliances
are not receiving the minimum inlet pressure the gas piping system may need to be changed.

CAUTION

Pipe

Size

Length (including fittings)

10'

20'

30'

40'

50'

60'

70'

80'

90'

100'

125'

150'

200'

(3m)

(6m)

(9m)

(12m)

(15m)

(18m)

(21m)

(24m)

(27m)

(30m)

(38m)

(45m)

(60m)

1/2"

275

189

152

129

114

103

96

89

83

78

69

63

55

3/4"

567

393

315

267

237

217

196

185

173

162

146

132

112

1"

1,071

732

590

504

448

409

378

346

322

307

275

252

213

1 1/4"

2,205

1,496

1,212

1039

913

834

771

724

677

630

567

511

440

1 1/2"

3,307

2,299

1,858

1,559

1,417

1,275

1,181

1,086

1,023

976

866

787

675

2"

6,221

4,331

3,465

2,992

2,646

2,394

2,205

2,047

1,921

1,811

1,606

1,496

1,260

Advertising