Electrolux EP19WI30LS User Manual

Page 24

Advertising
background image

22

Pipe

Size

Length (including fittings)

10'

20'

30'

40'

50'

60'

70'

80'

90'

100'

125'

(3m)

(6m)

(9m)

(12m)

(15m)

(18m)

(21m)

(24m)

(27m)

(30m)

(38m)

3/4"

360

247

199

170

151

137

126

117

110

104

92

1"

678

466

374

320

284

257

237

220

207

195

173

1 1/4"

1,390

957

768

657

583

528

486

452

424

400

355

1 1/2"

2,090

1,430

1,150

985

873

791

728

677

635

600

532

2"

4,020

2,760

2,220

1,900

1,680

1,520

1,400

1,300

1,220

1,160

1,020

2 1/2"

6,400

4,400

4,400

3,020

2,680

2,430

2,230

2,080

1,950

1,840

1,630

3"

11,300

7,780

7,780

5,350

4,740

4,290

3,950

3,760

3,450

3,260

2,890

4"

23,100

15,900

12,700

10,900

9,660

8,760

8,050

7,490

7,030

6,640

5,890

Table 1. For Less than 8” WC initial supply pressure

Maximum Natural Gas Delivery Capacity (0.5” Pressure Drop) [Schedule 40 Metalic Pipe]

Values in Table are in Cubic Feet of Gas per Hour (0.60 Specific Gravity, 0.5” Pressure Drop, inlet pressure less than 2psi). Contact your gas
supplier for BTU/Cubic Foot ratings. For simplification of your calculations, 1 Cubic Foot of Gas is approximately equivalent to 1000 BTU.

Instructions

1. Size each outlet branch starting from the furthest
using the Btuh required and the length from the meter.
2. Size each section of the main line using the length to
the furthest outlet and the Btuh required by everything
after that section.

Sample Gas Line

Sample Calculation - (Using 0.5” WC Pressure Drop Table)
Outlet A: 45' (13.5m) (Use 50' (15m)), 50,000 Btuh requires 1/2"
Outlet B: 40' (12m), 65,000 Btuh requires 1/2"
Section 1: 45' (13.5m) (Use 50' (15m)), 115,000 Btuh requires 3/4"
Outlet C: 30' (9m), 35,000 Btuh requires 1/2"
Section 2: 45' (13.5m) (Use 50' (15m)), 150,000 Btuh requires 3/4"
Outlet D: 25' (7.5m) (Use 30' (9m)), 25,000 Btuh requires 1/2"
Section 3: 45' (13.5m) (Use 50' (15m)), 175,000 Btuh requires 1"
Outlet E: 25' (7.5m) (Use 30' (9m)), 199,900 Btuh requires 1"
Section 4: 45' (13.5m) (Use 50' (15m)), 374,900 Btuh requires 1 1/4"

Natural Gas

Meter

Electrolux Condensing Tankless Gas Water Heater

(199,900 Btuh)

Clothes Dryer

(35,000 Btuh)

Barbecue

(50,000 Btuh)

Gas Range Stove

(65,000 Btuh)

10' (3m)

10' (3m)

10' (3m)

10' (3m)

5' (1.5m)

5' (1.5m)

5' (1.5m)

5' (1.5m)

5' (1.5m)

5' (1.5m)

Gas Fireplace

(25,000 Btuh)

Section 3 Section 2

Section 1

Outlet A

Outlet B

Outlet C

Outlet D

Outlet E

Section 4

Table 2. For 8” WC – 10.5” WC initial supply pressure

Maximum Natural Gas Delivery Capacity (3.0” Pressure Drop) [Schedule 40 Metalic Pipe]

Values in Table are in Cubic Feet of Gas per Hour (0.60 Specific Gravity, 3.0” Pressure Drop, 8.0” WC or greater supply pressure, inlet
pressure less than 2psi). Contact your gas supplier for BTU/Cubic Foot ratings. For simplification of your calculations, 1 Cubic Foot of
Gas is approximately equivalent to 1000 BTU.

Natural Gas

Meter

Electrolux Condensing Tankless Gas Water Heater

(199,900 Btuh)

Clothes Dryer

(35,000 Btuh)

Barbecue

(50,000 Btuh)

Gas Range Stove

(65,000 Btuh)

10' (3m)

10' (3m)

10' (3m)

10' (3m)

5' (1.5m)

5' (1.5m)

5' (1.5m)

5' (1.5m)

5' (1.5m)

5' (1.5m)

Gas Fireplace

(25,000 Btuh)

Instructions

1. Size each outlet branch starting from the furthest
using the Btuh required and the length from the meter.
2. Size each section of the main line using the length to
the furthest outlet and the Btuh required by everything
after that section.

Sample Gas Line

Sample Calculation (Using 3.0” WC Pressure Drop Table)
Outlet A: 45' (13.5m) (Use 50' (15m)), 50,000 Btuh requires 1/2"
Outlet B: 40' (12m), 65,000 Btuh requires 1/2"
Section 1: 45' (13.5m) (Use 50' (15m)), 115,000 Btuh requires 1/2"
Outlet C: 30' (9m), 35,000 Btuh requires 1/2"
Section 2: 45' (13.5m) (Use 50' (15m)), 150,000 Btuh requires 1/2"
Outlet D: 25' (7.5m) (Use 30' (9m)), 25,000 Btuh requires 1/2"
Section 3: 45' (13.5m) (Use 50' (15m)), 175,000 Btuh requires 1/2"
Outlet E: 25' (7.5m) (Use 30' (9m)), 199,900 Btuh requires 1/2"
Section 4: 45' (13.5m) (Use 50' (15m)), 374,900 Btuh requires 3/4"

Section 3 Section 2

Section 1

Outlet A

Outlet B

Outlet C

Outlet D

Outlet E

Section 4

Pipe

Size

Length (including fittings)

10'

20'

30'

40'

50'

60'

70'

80'

90'

100'

125'

(3m)

(6m)

(9m)

(12m)

(15m)

(18m)

(21m)

(24m)

(27m)

(30m)

(38m)

1/2"

454

312

250

214

190

172

158

147

138

131

116

3/4"

949

652

524

448

397

360

331

308

289

273

242

1"

1,787

1,228

986

844

748

678

624

580

544

514

456

1 1/4"

3,669

2,522

2,025

1,733

1,536

1,392

1,280

1,191

1,118

1,056

936

1 1/2"

5,497

3,778

3,034

2,597

2,302

2,085

1,919

1,785

1,675

1,582

1,402

2"

10,588

7,277

5,844

5,001

4,433

4,016

3,695

3,437

3,225

3,046

2,700

2 1/2"

16,875

11,598

9,314

7,971

7,065

6,401

5,889

5,479

1,540

4,856

4,303

3"

29,832

20,503

16,465

14,092

12,489

11,316

10,411

9,865

9,087

8,584

7,608

4"

43678

30,020

24,107

20,632

18,286

16,569

15,243

14,181

13,305

12,568

11,139

Advertising