Electrolux EXH12HL1WE User Manual

Page 12

Advertising
background image

12 www.electrolux.com

The remote control does not

work.

Is there any magnetic or electrical interference

near the unit? If yes, remove and reinsert the

batteries.
Is the remote control within its transmitting and

receiving range without any obstructions? If

necessary, replace the batteries.
Is the remote control damaged?

Water leakage in indoor unit.

The room humidity is high.
Condensing water overkows.
The drain hose is loose.

Water leakage in outdoor unit.

In COOL mode, water condensate is generated

around the pipes and connection joints.
In HEAT mode, the water on the heat

exchanger drips out.
In defrost mode, the thaw water kows out.

Noise from indoor unit.

The noise emitted when the fan or compressor

relay is switched on or off.
If the defrost mode is started or stopped, you

will hear the sound of refrigerant kowing in the

reverse direction.

The indoor unit cannot blow air.

In HEAT mode, when the temperature of the

indoor heat exchanger is low, the airkow is

stopped within 2 minutes in order to prevent

cold air.
In HEAT mode, when the outdoor temperature

is low or the outdoor humidity is high, frost will

be formed on the outdoor heat exchanger. The

unit will defrost automatically and the indoor

unit will stop blowing air for 3-12 minutes.
In DRY mode, the indoor fan will stop

blowing air for 3-12 minutes in order to avoid

condensing water being vapourised again.
In defrost mode, water or vapour may be

emitted.

Moisture on air outlet.

If the unit operates at high humidity for a long

time, moisture will be generated on the grill of

the air outlet.

C5: Malfunction of connector

jumper.

Check if the connector jumper contacts

properly. If necessary, replace the old circuit

board with a new circuit board.

F1: Malfunction of indoor ambient

temperature sensor.

Check if the indoor room temperature sensor is

connected properly.

Advertising