• Do not subject the mains cable to

force.

• The distance between the unit and

heat sources is at least 1.5 m.

• Use an air switch. The air switch must

have functions for magnetic tripping

and heat tripping to prevent short

circuit and overload. The suitable

capacity is specified in the following

table.

NOTE
• Make sure that the live wire, the

neutral wire and the ground wire

in the mains socket are properly

connected.

• Inadequate or incorrect electrical

connections can cause electric shock

or fire.

Grounding requirements
• The unit is a type I electrical

appliance. Make sure that the unit is

properly grounded.

• The yellow-green wire is the ground

wire that cannot be used for other

purposes. Improper grounding can

cause electric shock.

• The ground resistance must comply

with local regulations.

• The mains supply must have reliable

ground terminal. Do not connect

the ground wire to water pipes, gas

pipes, contamination pipes or other

possible unsafe places.

• Fuses must comply with the

prescribed model and rating printed

on the fuse cover or circuit board.

Air conditioner (Btu)

Air switch capacity

09-12K

16A