ENGLISH 15

refrigerant circuit because the circuit

operating temperature is high.

• The pipes connecting the indoor and

outdoor unit are not included in the

unit.

• The outdoor unit is powered by the

indoor unit.

Installation site

• Do not install the unit in areas with:
- strong heat sources;
- vapours or flammable gasses;
- contamination with oil particles;
- high frequency electromagnetic

equipment (e.g. welding equipment or

medical devices);

- high salinity (e.g. close to coastal

areas);

- sulphuric gas (e.g hot water springs);
- poor air quality.

Indoor unit
• Maintain the minimum installation

distances specified in this document.

Do not block the air inlet or the air

outlet.

• Do not use the unit in places with

extremely high humidity.

• Install the indoor unit out of reach of

children.

• The wall must be strong enough to

support the weight and vibration of

the unit.

• Install the indoor unit at least 50 cm

above the floor surface.

• Leave sufficient space for cleaning

and maintenance.

• The air filter should remain accessible.
• Leave at least 1 m distance

between the unit and other electrical

appliances.

• Install the indoor unit in a place where

the condensate water can be easily

drained.

• Install at a location protected from

direct sunlight.

Outdoor unit
• Maintain the minimum installation

distances specified in this document.

• Do not block the air inlet or the air

outlet.

• Install the outdoor unit out of reach of

children.

• Install the outdoor unit where there is

sufficient ventilation.

• Install the outdoor unit where

produced noise and airflow will not

disturb neighbors or animals.

• Install the outdoor unit in a dry place.
• Install the outdoor unit in a place not

exposed to direct sunlight or strong

wind.

• Install the unit in a place that supports

the weight and vibration of the unit.

• The height difference between the

indoor unit and the outdoor unit must

be less than 5 m.

• The length of the connecting pipes

must be less than 10 m.

• Leave sufficient space for cleaning

and maintenance.

• The outdoor unit is powered by the

indoor unit.

Safety precautions for electrical

appliances
• Use a dedicated mains circuit.
• The unit must be properly grounded.
• Install a Residual-current device

(RCD) to protect against personal

injury in case of leakage currents.

• Use an all pole disconnection switch

with a contact separation of at least

3 mm in all poles in fixed wiring. For

models with a mains plug, make sure

that the mains plug is within reach

after installation.

• The installation must comply with

local electrical safety regulations and

with other relevant local regulations

• The unit must be installed in

accordance with national wiring

regulations.