16. Securely tighten the cap of the

packed valves.

Outdoor condensate drainage (heat-

pump unit only)
During heating operation, condensate

water and defrosting water must be

drained through the drain hose.

1. Install the outdoor drain connector in

a Ø 25 mm hole on the base plate.

2. Attach the drain hose to the

connector so that water in the

outdoor unit can be drained. The

hole diameter 25 must be plugged.

Operation test

Before operation test
• Do not connect the unit to the power

supply before the installation is

completed.

• The electrical wiring must be

connected correctly and securely.

• The cut-off valves of the connection

pipes must be opened. Refer to the

section “Vacuuming and leakage

test”.

• The unit must be cleaned thoroughly.

Operation test method
1. Connect the unit to the power

supply.

2. Press the ON/OFF button to switch

on the unit.

3. Press the MODE button to set the

operation mode and check whether

the operation is as expected.

Check after installation

Items to be checked

Possible malfunction

Has the unit been jxed jrmly?

The unit may drop, shake or emit noise.

Have you done the refrigerant leakage

test?

Insufjcient cooling or heating.

Is the thermal insulation sufjcient?

Condensation.

Is the water drainage satisfactory?

Water leakage.

Is the voltage in accordance with the

rated voltage on the nameplate?

Electrical malfunction or damage to the

unit.

Is the electrical wiring or piping

connection installed correctly and

securely?

Electrical malfunction or damage to the

parts.

Has the unit been securely grounded?

Electrical leakage.

Is the mains cable as specijed?

Electrical malfunction or damage to

parts.

Is the air inlet or the air outlet blocked?

Insufjcient cooling or heating.

Is the length of the connection pipes

and the refrigerant capacity as specijed

Inaccurate refrigerant capacity.

Is the length of the connection pipes

and the refrigerant capacity as specijed

Inaccurate refrigerant capacity.