Indoor unit

Installing the mounting plate
1. Install the mounting plate

horizontally.

2. Fix the mounting plate to the wall

with screws. Make sure that the

mounting plate is fixed firmly enough

to support approximately 60 kg. The

weight must be evenly shared by

each screw.

Drill piping hole
1. Slant the piping hole (Ø 55 mm) on

the wall slightly downward to the

outdoor side.

2. Insert the piping-hole sleeve into

the hole to prevent damage to the

connection piping and wiring.

Installing the drain hose
1. Connect the drain hose to the outlet

pipe of the indoor unit. Bind the joint

with rubber belt.

2. Put the drain hose into the insulating

tube.

3. Wrap the insulating tube with wide

rubber belt to prevent the insulating

tube from shifting. Slant the drain

hose slightly downward for smooth

drainage of the condensate water.

NOTE
• The insulating tube must be

connected reliably with the sleeve

outside the outlet pipe. The

drain must be slanted downward

slightly without distortion, bulge or

fluctuation. Do not put the outlet of

the drain hose in water to prevent the

drain hose from freezing.

Electrical wiring indoor unit:

1

2 3 4

Nr.

Colour

1

Blue (neutral)

2

Black

3

Brown

4

Yellow (ground)

CAUTION

• Check the wiring to make sure that

there is no short circuit. Incorrect

wiring can cause malfunction.

1. Open the front panel.
2. Remove the wiring cover.
3. Fix the mains cord to the terminal

board (as shown).

4. Guide the mains cord through the

hole at the back of the indoor unit.

5. Install the cord anchorage and

wiring cover.

6. Close the front panel.

NOTE
• The electrical wiring between the

indoor unit and the outdoor unit

must be connected by a qualified

electrician.

• Tighten the terminal screws tightly.
• After tightening the screws, pull the

wire slightly to confirm whether it’s

firm or not.

• Make sure that the electrical

connections are properly grounded to

prevent electric shock.