Outdoor unit – Electrolux EXH12HL1WE User Manual

Page 19

Advertising
background image

ENGLISH 19

• Make sure that the wiring connections

are secure and that the cover plates

are properly mounted to prevent

electric shock.

Installing the indoor unit
The piping can be output from the right,

the right rear, the left or the left rear.
1. When routing the piping and wiring

from the left or right of indoor unit,

cut off the tailings from the chassis

when necessary.

2. Remove the piping from the body

case.

3. Wrap the piping, the mains cords

and the drain hose with the tape.

4. Guide the piping, the mains cords

and the drain hose through the

piping hole.

5. Firmly hang the mounting slots of

the indoor unit on the upper hooks

of the mounting plate.

6. The installation site must be at least

50 cm above the floor surface.

Installing the connection pipe
1. Align the center of the piping flare

with the related valve.

2. Screw in the flare nut by hand and

then tighten the nut with spanner

and torque wrench. Refer to the

following table.

Hex nut

diameter (mm)

Tightening

torque (Nm)

Ш 6

15-20

Ш 9.52

30-40

Ш 12

45-55

Ш 16

60-65

Ш 19

70-75

NOTE
• First connect the connection pipe

to the indoor unit and then to the

outdoor unit. Handle the piping

bending with care. Do not damage

the connection pipe. Firmly tighten

the joint nut to prevent leakage.

• The pipes connecting the indoor and

outdoor unit are not included in the

unit.

• In case the connective pipe length is

longer than 7.5m charge the unit with

additional refrigerant. Add 20g/m of

R410A for models with a capacity of

less than 6500W. Add 50g/m for the

other models.

Outdoor unit

Electrical wiring

1

2 3 4

Nr.

Colour

1

Blue (neutral)

2

Black

3

Brown

4

Yellow (ground)

CAUTION

• Check the wiring to make sure that

there is no short circuit. Incorrect

wiring can cause malfunction.

1. Remove the handle (x2) on the right

side plate of outdoor unit.

2. Remove mains cord anchorage.
3. Connect the mains cord to the

terminal board.

4. Lock the position of the cord with

wire clamps.

5. Check for improper connections.

Advertising