Replacement of the connection cable, Assembly – Electrolux EQW4111BOG User Manual

Page 61

Advertising
background image

formity with the standard and regulations
force.

• The power cable must be placed in such

a way that it does not touch any hot
part.

• Connect the appliance to the mains with

a device that lets to disconnect the ap-
pliance from the mains at all poles with a
contact opening width of minimum 3
mm, eg. automatic line protecting cut-
out, earth leakage trips or fuse.

• None of a parts of the connection cable

can not get a temperature 90°C.

REPLACEMENT OF THE
CONNECTION CABLE

In order to replace the connection cable
speak your local Service Force Centre!
To replace the connection cable use only
H05BB-F Tmax 90°C (or higher) type.
Make sure that the cable section is applica-
ble to the power and the working tempera-
ture. The yellow/green earth wire must be
approximately 2 cm longer than all phase
wires.

ASSEMBLY

min.

50mm

min.

450mm

min.

650mm

=

=

340

+1

mm

600mm

490

+1

mm

R 5mm

min.

30 mm

min. 20 mm

• Seal the gap between the worktop and

glass ceramic with silicone.

• Put some soapy water on the silicone.

ENGLISH