Allied Air Enterprises 80G1UH User Manual

Page 25

Advertising
background image

506526-01

Page 25 of 39

Issue 1031

Leak Check

After gas piping is completed, carefully check all piping

connections (factory and field installed) for gas leaks. Use

a leak detecting solution or other preferred means.

NOTE: If emergency shutoff is necessary, shut off the main

manual gas valve and disconnect the main power to the

furnace. The installer should properly label these devices.

Some soaps used for leak detection are corrosive to

certain metals. Carefully rinse piping thoroughly after

leak test has been completed. Do not use matches,

candles, flame or other sources of ignition to check for

gas leaks.

CAUTION

The furnace must be isolated by closing its individual manual

shut-off valve and disconnecting from from the gas supply

system the during any pressure testing of the gas supply

system at pressures less than or equal to 1/2 psig (3.48

kPa, 14 inches w.c.).

Electrical

ELECTROSTATIC DISCHARGE (ESD)

Precautions and Procedures

Figure 28

When testing pressure of gas lines, gas valve must be

disconnected and isolated. See Figure 28. Gas valves

can be damaged if subjected to pressures greater than

1/2 psig (3.48 kPa, 14 inches w.c.).

IMPORTANT

Electrostatic discharge can affect electronic

components. Take precautions during furnace

installation and service to protect the furnace’s electronic

controls. Precautions will help to avoid control exposure

to electrostatic discharge by putting the furnace, the

control and the technician at the same electrostatic

potential. Neutralize electrostatic charge by touching

hand and all tools on an unpainted unit surface, such

as the gas valve or blower deck, before performing any

service procedure.

CAUTION

The unit is equipped with a field make-up box on the left

hand side of the cabinet. The make-up box may be moved

to the right side of the furnace to facilitate installation. If the

make-up box is moved to the right side, clip the wire ties

that bundle the wires together. The excess wire must be

pulled into the blower compartment. Secure the excess wire

to the existing harness to protect it from damage.

Refer to Figure 32 for schematic wiring diagram and

troubleshooting and Figure 33 for field wiring.

The power supply wiring must meet Class I restrictions.

Protected by either a fuse or circuit breaker, select circuit

protection and wire size according to unit nameplate.

NOTE: Unit nameplate states maximum current draw.

Maximum over current protection allowed is 15 AMP.

Holes are on both sides of the furnace cabinet to facilitate

wiring.

Install a separate (properly sized) disconnect switch near

the furnace so that power can be turned off for servicing.

INTERIOR MAKE-UP BOX INSTALLATION

Figure 30

INTERIOR MAKE-UP BOX INSTALLATION

Figure 29