9. Remove screws from both sides, top and bottom of

vestibule panel.

10. Remove heat exchanger. It may be necessary to spread

cabinet side to allow more room. If so, remove five

screws from the left side or right side of cabinet. See

Figure 40.

11. Backwash using steam. Begin from the bumer opening

on each clam. Steam must not exceed 275°F.

12. To clean burners, run a vacuum cleaner with a soft brush

attachment over the face of burners. Visually inspect

inside the burners and crossovers for any blockage

caused by foreign matter. Remove any blockage. Figure

38 shows burner detail.

13. To clean the combustion air inducer visually inspect and

using a wire brush clean where necessary. Use

compressed air to clean off debris and any rust.

14. Reinstall heat exchanger in vestibule. (Replace the five

screws in the cabinet from step 10 if removed).

15. NOx units only - Replace NOx inserts.

16. Reinstall collector box and combustion air assembly.

Reinstall all screws to the collector box and combustion

air inducer. Failure to replace all screws may cause

leaks. Inspect gaskets for any damage and replace if

necessary.

17. Reinstall burner box, manifold assembly and burner box

cover.

NOx INSERTS

Figure 39

Remove 5 Screws If Necessary

(either side of cabinet)

Figure 40

18. Reconnect all wires.

19. Reconnect top cap and vent pipe to combustion air

inducer outlet.

20. Reconnect gas supply piping.

21. Turn on power and gas supply to unit.

22. Set thermostat and check for proper operation.

23. Check all piping connections, factory and field, for gas

leaks. Use a leak detecting solution or other preferred

means.

24. If a leak is detected, shut gas and electricity off and

repair leak.

25. Repeat steps 24 and 26 until no leaks are detected.

26. Replace access panel.

Some soaps used for leak detection are corrosive to

certain metals. Carefully rinse piping thoroughly after

leak test has been completed. Do not use matches,

candles, flame or other sources of ignition to check for

gas leaks.

CAUTION