At the beginning of each heating season, a qualified

technician should check the system as follows:

Blower

Check the blower wheel for debris and clean if necessary.

The blower motors are prelubricated for extended bearing

life. No further lubrication is needed.

Filters

Filters are installed external to the unit. Filters should be

inspected monthly. Clean or replace the filters when

necessary to ensure that the furnace operates properly.

Replacement filters must be rated for high velocity airflow.

Table 1 lists recommended filter sizes.

Flue And Chimney

1. Check flue pipe, chimney and all connections for

tightness and to make sure there is no blockage.

2. Check unit for proper draft.

Electrical

1. Check all wiring for loose connections.

2. Check for the correct voltage at the furnace (furnace

operating). Correct voltage is 120VAC ± 10%.

3. Check amp draw on the blower motor with inner blower

panel in place.

Unit Nameplate___________Actual_______________

The blower access panel must be securely in place when

the blower and burners are operating. Gas fumes, which

could contain carbon monoxide, can be drawn into living

space resulting in personal injury or death.

WARNING

Service

ELECTRICAL SHOCK, FIRE,

OR EXPLOSION HAZARD.

Failure to follow safety warnings exactly could result in

dangerous operation, serious injury, death or property

damage.

Improper servicing could result in dangerous operation,

serious injury, death, or property damage. Before

servicing, disconnect all electrical power to furnace.

When servicing controls, label all wires prior to

disconnecting. Take care to reconnect wires correctly.

Verify proper operation after servicing.