Controlling the multiple product, Rs-232c, Transmission / receiving protocol – LG M3202C-BA User Manual

Page 56

Advertising
background image

Controlling the Multiple Product

RS-232C

A16

26. Temperature value (Command : d n)

To read the inside temperature value.

Transmission

[d][n][][Set ID][][Data][x]

* The data is always FF(in Hex).

Acknowledgement

[n][][Set ID][][OK/NG][Data][x]

* The data is 1 byte long in Hexadecimal.

27. Lamp fault Check(Command : d p)

To check lamp fault.

Transmission

[d][p][][Set ID][][Data][x]

* The data is always FF(in Hex).

Acknowledgement

[p][][Set ID][][OK/NG][Data][x]

Data 0 : Lamp Fault

1: Lamp OK

Transmission / Receiving Protocol