ADTRAN 1200214L1 User Manual

Page 106

Advertising
background image

82

IQ Probe User Manual

61200214L1-1

Chapter 10. Statistics

DBU State

Current state of the DBU circuit.

Interval Remaining

Number of seconds remaining in the current timed interval.
This field is only shown in View by Interval menus.

Rx Frames

Number of frames received by the DBU port.

Rx Bytes

Number of bytes received by the DBU port.

Maximum Rx Throughput

Maximum throughput sample in the receive direction for the
given interval. This is displayed in kbps.

Average Rx Throughput

Average throughput in the receive direction for the given
interval. This is displayed in kbps.

Maximum Rx Utilization

Maximum utilization sample in the receive direction for the
given interval. Utilization is displayed as a percent of DBU port
bandwidth.

Average Rx Utilization

Average utilization sample in the receive direction for the given
interval. Utilization is displayed as a percent of DBU port
bandwidth.

Tx Frames

Number of frames transmitted by the DBU port.

Tx Bytes

Number of bytes transmitted by the DBU port.

Maximum Tx Throughput

Maximum throughput sample in the transmit direction for the
given interval. This is displayed in kbps.

Advertising