94

IQ Probe User Manual

61200214L1-1

Chapter 10. Statistics

Signal Errors

Total signal frames received with PVC signaling protocol viola-
tions.

Errored Frames

Total errored frames received since last reset.

CRC Errors

Number of frames received with CRC violations.

Abort Frames

Total frames received without a closing flag.

Octet Align

Number of frames received with a bit count that does not fall on
8-bit boundaries.

Signal Down Time

Time in seconds that signaling state has been down.

DCE Port Statistics Available on Front Panel

Control Signal Status Screen

An asterisk (*) indicates that the signal is active for the DCE port.

RS

request to send

TR

data terminal ready

CS

clear to send

CD

carrier detect

SR

data set ready

DBU Status

Current state of the incoming DBU circuit (only appears if an
ESP DBU card is installed).

Signal State

Current state of the DCE port (up or down).

Signal State Change

Number of changes in the signaling protocol state.