HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 181

Advertising
background image

Virtual Connect modules 181

Row

Description

Enclosure Name

Name of the enclosure (assigned through the Onboard Administrator)

Bay

Number of the bay being summarized on this screen

Module Host Name

Includes controls that enable you to set a custom host name for the module and
reset the module

Power Status/Control

Power state of the device

The following table describes the rows within the Interconnect Bay Information table in the Bay Summary
screen.

Row

Description

Part Number

The part number to be used when ordering an additional module of this type

Product Name

The common descriptive name of the module

Serial Number

The unique serial number of the module

Dip Switch Setting

The current physical setting of the system maintenance switches in a

hexadecimal format, where the least significant four bits of the value
correspond to the four switches and a bit value of 1 indicates the switch is in
the "on" position.

Spare Part Number

The part number to be used when ordering a replacement module of this type

Manufacturer

The manufacturer of the module

Firmware Rev

The current firmware revision of the module

The following table describes the columns within the Uplink Port Information table in the Bay Summary
screen.

Column

Description

Label

Uplink port number

Network(s)

Network name or the name of the shared uplink associated with this port

Status

Shows the link status, link speed, and connectivity of the port. If the port is
unlinked and no connectivity exists, the cause is displayed. For more
information about possible causes, see "Port status conditions (on page

203

)."

Connector Type

Displays the physical type of the faceplate connector, type of pluggable
module if one is present, or "Internal" to indicate the inter-switch link is active
on the VC-Enet module.

LAG ID

Identifies the group of ports that have been aggregated together to form an
802.3ad Link Aggregation Group. This ID is unique only within a single

VC-Enet module, meaning the same LAG ID can be used on different VC-Enet
modules, but it is only meaningful for ports within the same VC-Enet module.

Connected to

Displays the MAC address of the device that this port is connected to on the

other end. The remote device must support LLDP to display this information.

Detailed Statistics

Click to display detailed statistics about this port.

The following table describes the columns within the Server Port Information table in the Bay Summary

screen.

Column

Description

Label

Server side port number (determined by the device bay and NIC)

Flex NIC

Flexible network interface card port

Physical server

Number of the device bay and a description of the installed server blade