Snmp configuration (vc-fc) – HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 37

Advertising
background image

Virtual Connect domains 37

To select a trap severity, do one of the following:

Highlight the item, and then click the right arrow.

Highlight the item, and then drag and drop it into the right window.

For a definition of trap severities, see "Trap severities (on page

33

)." When an event causes a trap to be

generated with the severity listed in the right window, it is sent to the trap destination. For VC-FC modules, the
trap severity is fixed at INFORMATIONAL and cannot be modified.
If you do not have the required privileges to select a category, that section is disabled. For a listing of trap
categories and the required administrative privileges, see "Trap categories and required administrative
privileges (on page

33

)."

SNMP Configuration (VC-FC)

By enabling SNMP for VC-FC modules, network management systems can monitor the VC-FC modules in the

domain for events, such as warnings and errors, which might require corrective actions. You must have
storage or domain administrator privileges to administer FC SNMP settings.
The VC-FC SNMP settings apply to all VC-FC modules in the VC domain.

The following table describes the fields within the SNMP Configuration screen.

Field name

Description

Enable SNMP

Select to enable SNMP.

Enable SMI-S

Select to enable SMI-S

System Contact

Specify a contact name for this system when SNMP is enabled. The maximum
length is 20 characters.

Read Community

Controls SNMP read access when SNMP is enabled. The default value is "public".

Advertising