Smi-s overview, Viewing the system log – HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 38

Advertising
background image

Virtual Connect domains 38

Field name

Description

The read community string must always be set when SNMP is enabled. The

maximum length is 24 characters.

SNMP Trap Destinations

SNMP trap destination table

Destination

User-designated name for the trap destination. The Destination name must be

unique.

IP Address

IPv4 address for the trap destination. DNS name is not supported.

Community String

The Community String acts like a password for a given trap destination. The
trap-receiving application can use the community string to filter the incoming traps.
Default: public

Format

Format of the new trap (SNMPv1)

Action

Perform edit and delete operations

The following table describes the available actions in the SNMP Configuration screen. Clicking another link
in the pull-down menu or left navigation tree causes current edits that have not been applied to be lost.

Task

Action

Add an SNMP trap destination
("

Adding an SNMP trap

destination

" on page

36

)

Click Add below the destination table, or right-click on the header row of
the destination table, and then select Add Destination.

Edit an SNMP trap destination

Click Edit in the Action column, or right-click on the trap destination row,
and then select Edit Destination.

Delete an SNMP trap destination Click Delete in the Action column, or right-click on the trap destination

row, and then select Delete Destination.

Save changes

Click Apply.

SMI-S overview

The SMI-S was created by SNIA to standardize storage management solutions. SMI-S replaces multiple

disparate managed object models, protocols, and transports with a single object-oriented model for each
type of component in a storage network. SMI-S enables management applications (such as HP SIM) to
support storage devices from multiple vendors quickly and reliably because they are no longer proprietary.

SMI-S detects and manages storage elements by type, not by vendor.
The ability to enable or disable SMI-S is not available on the HP VC 8Gb 24-Port FC module.
You must have storage or domain administrative privileges to configure SMI-S capabilities.

Viewing the system log

Use the following screens to view and configure domain system log information:

System Log (System Log) screen (on page

39

)

o

View logged information events within VCM

System Log (Configuration) screen (on page

41

)

o

View remote log destination settings

o

Set remove log destination settings

Advertising