Table 7 Recovery Manager for Microsoft Exchange Event Messages (continued)

Description/Action

Error Message

Event ID

Multiple files from the storage group share volumes.

Check the file path and volume mapping to
determine which volume is shared with the other
storage group(s). Unmount this shared volume.

RME3204: ERROR: Two or more files of this
storage group share volume(s). Please
unmount the shared volume(s) before
proceeding.

3204

The virtual copy was not mounted before attempting
to restore.

Mount the virtual copy and then try a file copy
restore.

RME3205: ERROR: Mount this Virtual Copy
before running restore.

3205

The virtual copy was not unmounted before
promoting the restore.

Unmount the virtual copy and then try a volume
promote restore.

RME3206: ERROR: Unmount this Virtual
Copy before running promotion restore.

3206

All mailbox stores within the storage group were
not unmounted before attempting a restore.

Unmount all mailboxes in the storage group and
then try to restore.

RME3210: ERROR: Unmount all mailbox
stores within a storage group before
attempting a restore.

3210

All public folder stores within the storage group
were not unmounted before attempting a restore.

Unmount all public folder stores in the storage
group and then try to restore.

RME3212: ERROR: Unmount all public
folder stores within a storage group before
attempting a restore.

3212

All databases in the storage group were not
unmounted before attempting a restore.

Unmount all databases in the storage group and
then try to restore.

RME3213: ERROR: All databases in the
storage group must be dismounted to
perform a restore.

3213

Promotion of the specified volume has failed.

Consult the Windows event log for the specific
error message.

RME3216: ERROR: Promotion of volume
<Volume Name> failed.

3216

A restore for the specified backup could not be
performed.

Check the syntax for the RMExch backup
command.

RME3220: ERROR: The backup you would
like to restore is not found. Please check your
parameters.

3220

The database or log target volume cannot be spread
across multiple HP 3PAR Storage Systems as this
configuration is not supported.

Refer to the required setup and configuration.

RMCOMN3501: ERROR: The volume is
spread across multiple InServs. This
configuration isn't supported.

3501

An invalid timeout value has been specified.

Verify that the specified timeout value is within
the supported range of 3 minutes (180 seconds)
to 10 minutes (600 seconds).

3PARVSS3801: ERROR: Invalid timeout
value specified. The valid range is <number
1> to <number 2> seconds.

3801

An invalid retry value has been specified.

Verify that the specified retry value is within the
supported range of 0 to 10.

3PARVSS3802: ERROR: Invalid retry value
specified. The valid range is <number 1> to
<number 2>.

3802

The connection setup could not be accessed.

Verify that the HP 3PAR VSS Provider Software
Registry Key is still valid on the system. If the
Registry Key cannot be found, reinstallation is
required.

3PARVSS3803: ERROR: Unable to access
connection setup.

3803