Managing Switches

Configuring port threshold alarms

You can configure the switch to generate alarms for selected events. Configuring an alarm involves the

following:

Choosing an event type

Specifying rising and falling triggers

Specifying a sample window

Enabling or disabling the alarm

To configure port threshold alarms:

1.

Select a switch in the fabric tree.

2.

Select Switch > Port Threshold Alarm Configuration to open the Port Threshold Alarm Configuration

dialog box (

Figure 49

).

Figure 49

Port Threshold Alarm Configuration dialog box

3.

Select the Enable All Port Threshold Alarms option to enable monitoring for all the individual alarm

types that are enabled. The Enable All Port Threshold Alarms option is the master control for the

individual alarms. For example, the switch monitors CRC errors only if both the CRC Error Enable and

Enable All Port Threshold Alarms options are selected.

4.

Select an event type from the Port Threshold Alarm drop-down list. Choose from the following options:
• CRC error monitoring
• Decode errors monitoring
• ISL monitoring
• Login monitoring
• Logout monitoring
• Loss of signal monitoring

5.

Select the Enable option to make the alarm eligible for use.

6.

Enter a value for the rising trigger. A rising trigger alarm is generated when the event count per interval

exceeds the rising trigger. The switch does not generate another rising trigger alarm for that event until

the count descends below the falling trigger and rises again above the rising trigger. Consider the

example in

Figure 50

.

7.

Enter a value for the falling trigger. A falling trigger alarm is generated when the event count per

interval descends below the falling trigger.