HP Intelligent Infrastructure Analyzer Software User Manual

Page 18

Advertising
background image

NOTE:

The Default value for CIMOM Port is 5988.

The Default value for Read Community is public.

While installing HP CIMServer on the remote host, and if the user has used a non default
port then, enter the same here.

3.

Click Start Discovery to start the discovery process.

Based on the discovery-protocol-specific authentication process, all connected switches
are discovered and follow the step specified in 1a.

Based on the discovery-protocol-specific authentication process, it discovers all the
switches within the IP address range and follow the step specified in 1b.

4.

The discovered switches are displayed with the following details: IP Address, Switch
Name, Vendor, Model, State, Edit, and Status as shown in

Figure 7 (page 18)

.

Figure 7 Discovered Switches

For information on switch states, see

“Switch Details” (page 19)

.

5.

Select the check box of the discovered switch(es) to perform one of these actions:

Click on Monitor switch(es) to perform the data collection, monitoring, and SFP
diagnostics.

Delete – removes the components from the profile.

Test connectivity – tests the network connectivity of the components.

6.

Click Next, to select the Hosts to be monitored.

The following message is displayed if no switches are selected for monitoring:

18

Using HP IIAS

Advertising