The port must be configured as a target attached to a Windows host.
Set system parameters according to the following table. For connection parameters not shown,
refer to SGI IS4600 series documentation.

Parameter Setting

Parameter

When alternate paths are connected to different clusters
on the SGI IS4600 series side: Linux

host type

3Par T800, F400, V800, V400 series

The port must be configured as a target attached to a windows host.
Set system parameters according to the following tables. For connection parameters not shown,
refer to 3Par T800, F400, V800 or V400 series documentation.
For 3Par T800 and F400 series

Parameter Setting

Parameter

generic-legacy (or generic)

host mode

For 3Par V800 and V400 series

Parameter Setting

Parameter

generic-legacy

host mode

The volumes in which "Dynamic optimization" or "Adaptive optimization" is applied must not be
used as the external volume of VSP; otherwise the performance of the external volume may possibly
be degraded and the operation cannot be guaranteed.

Storage system with a product name displayed as "(generic)"

The generic External Storage profile (available with 70-04-x) provides support for connecting Fibre
channel attached, external storage systems without testing them individually. It will automatically
support storage systems that conform to a subset of the standard SCSI Primary Commands. (If you
need further information, please contact the HP Technical Support). An HP representative can
perform a step-wise process to install and connect external storage. These steps (defined below)
follow a standard process to ensure that no obvious problems exist in the virtualization. Updating
a P9500 to the minimum firmware level 70-05-0x automatically installs the generic Ext Stor profile
and makes it available.

Support conditions when product name displays as “(Generic)”

When an external storage system is connected to a P9500 and is supported with the generic Ext
Stor profile, the following support conditions exist.

Vendor name that corresponds to the external storage system is displayed.

Product name is displayed as “Generic”.

NOTE:

If multiple generic storage systems of the same vendor are connected, they are

displayed as a single storage system. As a result, if Disconnect External Storage Systems or
Reconnect External Storage Systems is run for generic storage systems, all the generic storage
system volumes are disconnected or reconnected. For disconnecting or reconnecting a particular
generic storage system volume, the best practice is to run the command in the external volume
unit rather than the external storage system unit.

Serial number is not displayed.