HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 149

Advertising
background image

Server management 149

4

Start with modules in Bays

3 and 4, create a profile

(add 2 connections),
hotplug modules into Bays

5 and 6, then edit the

profile

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 3

4

Bay 4

Bay 3 Bay 4

Bay 5 Bay 6

Add connection is

disallowed because the

current FC module
configurations do not

match the existing

connections in the
profile.

This profile will not be

useful after the hotplug.

To resolve this issue,
delete connections 3 and

4, save the profile, and

then scenario 4 applies.

5

Start with modules in Bays

3-6, create a profile,

hotplug modules into Bays
7 and 8, then edit the

profile and add

connections

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

Bay 3 Bay 4

Bay 5 Bay 6
Bay 7 Bay 8

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

5

Bay 7

6

Bay 8

Add connection, 2 times

6

Start with modules in Bays

3-6, create a profile (add
4 connections), hotplug

modules into Bays 7 and

8, then edit the profile

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

5

Bay 3

6

Bay 4

7

Bay 5

8

Bay 6

Bay 3 Bay 4
Bay 5 Bay 6

Bay 7 Bay 8

Add connection is

disallowed because the
current FC module

configurations do not

match the existing
connections in the

profile.

This profile will not be

useful after the hotplug.
To resolve this issue,

delete connections 5-8,

save the profile, and then
scenario 6 applies.

7

Start with modules in Bays

5 and 6, create a profile,

hotplug modules into Bays
3 and 4, then edit the

profile

Port

Connected to

1

Bay 5

2

Bay 6

Bay 3 Bay 4

Bay 5 Bay 6

Add connection is

disallowed because the

current FC module
configurations do not

match the existing

connections in the
profile.

8

Start with modules in Bays

5-8, create a profile,
hotplug modules into Bays

3 and 4, then edit the

profile

Port

Connected to

1

Bay 5

2

Bay 6

4

Bay 7

5

Bay 8

Bay 3 Bay 4
Bay 5 Bay 6

Bay 7 Bay 8

Add connection is

disallowed because the
current FC module

configurations do not

match the existing

connections in the
profile.

Advertising