Using multiple enclosures – HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 10

Advertising
background image

Overview 10

A basic Virtual Connect domain includes a single HP c-Class BladeSystem c7000 Enclosure for a total of 16

servers (or up to 32 servers if the double-dense option is enabled), or a single HP c-Class BladeSystem c3000
Enclosure for a total of eight servers (or up to 16 servers if the double-dense option is enabled). Within the

domain, any server blade can access any LAN or SAN connected to a VC module, and a server blade can

be used as a spare for any server blade within the same enclosure.
By stacking (cabling) the Ethernet or FlexFabric modules within the domain and connecting the FC or
FlexFabric modules to the same set of FC SANs, every server blade in the domain can be configured to

access any external network connection. With this configuration, the administrator can use Virtual Connect

Manager to deploy and migrate a server blade profile to any server in the Virtual Connect domain without

changing external LAN or SAN configurations.

Using multiple enclosures

Multiple enclosure support enables up to four c7000 enclosures to be managed within a single Virtual

Connect domain for a total of 128 servers, if double-dense support is enabled. Multiple enclosure domains
are not supported on c3000 enclosures. The VC-Enet or FlexFabric modules use stacking cables between

enclosures so that network traffic can be routed from any server Ethernet port to any uplink within the VC

domain.
By stacking (cabling) the Ethernet or FlexFabric modules within the domain, every server blade in the domain
can be configured to access any external network connection. Fibre Channel or FlexFabric modules within

different enclosures are each connected directly to the same set of FC SANs. With this configuration, the

administrator can use Virtual Connect Manager to deploy and migrate a server blade profile to any server

in the Virtual Connect domain without changing external LAN or SAN configurations.
When using multiple c7000 enclosures, there is a limit to the number of modules supported across the
enclosures within a domain. A total of 16 Ethernet and 16 VC-FC type modules can be installed. A FlexFabric

module counts as 1 Ethernet and 1 VC-FC module. Thus, up to 16 FlexFabric Modules or combinations of

FlexFabric, VC-Enet, and VC-FC modules are allowed as long as the 16-module limit for each module type

(Ethernet and FC) is not exceeded in the domain.
The management interfaces for all enclosure OAs and VC modules within the same VC domain must be on

the same lightly loaded subnet. The OA IP addresses used must be configured to be static. OA User

credential for all enclosure must be consistent to allow VCSU firmware updates for VC modules in the remote

enclosures.
Multi-enclosure double dense domains require similar and compatible FC modules in bays 5, 6, 7, and 8 in

all enclosures. If a multi-enclosure double dense configuration contains incompatible FC modules in bays 5,

6, 7, or 8 in either the local or remote enclosures, some or all of the compatible FC modules in the remote

enclosures might be designated INCOMPATIBLE after import.

Advertising