Server management 145

The Virtual Connect Manager may reset when creating and assigning many server profiles using VCEM. This

behavior has been seen when creating more than 100 server profiles all at once.

Server blade power on and power off guidelines

Certain server profile changes require the server blade in the device bay to be powered off before the

change can be made. HP recommends that administrators power off servers with the server console before
attempting such operations within the Virtual Connect Manager. The Virtual Connect Manager also provides

an opportunity to power off the server blade before such operations.
If any changes are made that require modifications to the server, the server blade must be powered off.

Network or Fabric changes do not require the server blade to be powered off. Server side settings include the
following:

Assigning a VC- or user-defined MAC address

Changing the PXE setting

Assigning a VC-defined WWN

Changing the Fibre Channel boot parameters

IMPORTANT:

For Virtual Connect v2.1x, the server blade must be powered off for all profile

changes if a Flex-10 NIC is installed in the server, and the server is connected to an HP Virtual

Connect Flex-10 Module or to an empty bay.

If any of the listed settings are changing, the server must be powered off before the profile action can occur.

If the server blade is not powered off, a message appears and no changes are made. In this case, power off
the server blade and repeat the action.
When server side settings are changing, the following operations require that server blades be powered off:

Assigning a profile to a server blade already installed in a device bay

Deleting a profile, moving a profile to a different device bay, or unassigning a profile from the existing
bay

Making modifications to a profile that affect settings on the server blade; for example, PXE

enable/disable, changing the number of connections, or changing Fibre Channel boot parameters

When assigning a VC-Assigned serial number (logical)

The following operations do not require the server blade to be powered off:

Changing the network connected to an already defined Ethernet port

Changing the Fabric connected to a Fibre Channel port

Changing the speed of a Fibre Channel port

Assigning or unassigning server profiles, if server factory defaults are used for MAC addresses and
WWNs, and BIOS Fibre Channel boot settings are used

Flex-10 connection changes that require power off
With Virtual Connect Manager v2.1x, always power off server blades, with Flex-10 connections, in the

following instances:

Changing a connection's network*:

o

From "unassigned" to a single network

o

From a single network to "unassigned"