Server management 148

General requirements for adding FC or FCoE

connections

In general, adding additional FC and FCoE connections is allowed during profile add and edit operations.

There are some specific cases under which it is not allowed.

When a profile is added, the FC/FCoE connections initially displayed are based on the FC/FCoE
module configuration in the domain, respectively. There will be two connections for a pair of

horizontally adjacent FC/FCoE capable modules.

Connections can only be added or removed “from the bottom.” You can only add or delete connections

at the end of the list.

You can remove connections at any time (one at a time, from the bottom).

If the existing profile connections do not match the current FC/FCoE module configurations, then the
add operation is not allowed.

The current maximum number of FC/FCoE connections is four per I/O bay.

The following table lists several scenarios that describe how adding FC/FCoE connections will affect an

existing profile. The table uses FC module configurations and FC modules as an example, but the same

scenarios are true for FCoE module configurations and FCoE capable modules.

Scenario

Description

Existing profile

connections

Current FC module

configurations

Adding profile

connections

1

Start with modules in Bays
3 and 4, create a profile,

then edit the profile and

add connections

Port

Connected to

1

Bay 3

2

Bay 4

Bay 3 Bay 4

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 3

4

Bay 4

Add connection, 2 times

2

Start with modules in Bays

3-6, create a profile, then
edit the profile and add

connections

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

Bay 3 Bay 4
Bay 5 Bay 6

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

5

Bay 3

6

Bay 4

7

Bay 5

8

Bay 6

Add connection, 4 times

3

Start with modules in Bays

3 and 4, create a profile,
hotplug modules into Bays

5 and 6, then edit the

profile and add
connections

Port

Connected to

1

Bay 3

2

Bay 4

Bay 3 Bay 4
Bay 5 Bay 6

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

Add connection, 2 times

Advertising