HP ProLiant DL760 G2 Server User Manual

Page 93

Advertising
background image

Installing Hardware Options, Server Power Off

To install a processor board option kit (with four processors) into the processor and
memory module:

WARNING: The processor and memory module weighs more than 35 lb.
HP recommends either removing ALL of the memory cartridges before
handling the module, or having two people handling the module together.

1. Back up all data on the server.

2. Shut down the operating system as directed by your operating system

instructions.

3. If the server was not powered down in the previous step, power down the server

(refer to Chapter 7).

4. Disconnect the power cords from the server.

5. Remove the processor and memory module (refer to Chapter 3).

WARNING: To reduce the risk of personal injury from hot surfaces, allow
the internal system components to cool before touching them.

6. Remove the processor board air baffle by pressing in the release tab (1) while

pulling the air baffle up (2).

Figure 4-3: Removing the processor board air baffle

4-4

HP ProLiant DL760 Generation 2 Server User Guide

HP CONFIDENTIAL

Writer: Jennifer Hayward File Name: e-ch4 Installing Options-Power Off.doc

Codename: Pioneer Part Number: 201264-002 Last Saved On: 6/17/03 9:32 AM