Server Power

7. Watch for memory system initialization. As the system initializes, the memory

cartridge power LEDs on all five memory cartridges begin blinking. After the
memory system is initialized, all memory cartridges power LEDs will illuminate
solid.

8. The server begins the Power-On Self-Test (POST) sequence. The IMD displays

each step of the POST sequence.

Power-On Self-Test

As the POST process continues during server power-up, you need to:

1. Check for the IMD messages about:

a. Server name

b. LCD firmware

c. System initialization

d. PCI auto configuration

e. Video

f. Processors

2. Check the IMD video initialization message. If a monitor is connected, refer to

the HP initialization screen.

3. Check the IMD memory test message. The monitor displays the memory

initialization, memory detected, and redundant memory.

4. Check the IMD processors message. The monitor displays the number, speed,

and cache size of the processors.

5. Check for IMD messages about:

a. Diskette drive

b. Option ROM

c. SCSI devices

HP ProLiant DL760 Generation 2 Server User Guide