HP 3000 Enterprise Virtual Array User Manual

Page 217

Advertising
background image

i.

Select the Initiator in the left-hand column of the Discovered ISCSI Initiator list.

ii.

Click the Information tab.

iii.

Select the Enable CHAP check box.

iv.

Enter a CHAP secret. For example:

CHAPsecret01

b.

To enable CHAP for the mpx100/100b Discovered iSCSI Initiator entry using the
mpx100/100b CLI:
• If the iSCSI Initiator is not listed under the Show Initiators command:

i.

Enter the initiator add command and add the iSCSI Initiator that is about to
do discovery.

ii.

Enable CHAP and enter a CHAP secret. For example:

CHAPsecret01

• If the iSCSI Initiator is already listed under the Show Initiators command:

i.

Enter the initiator mod command and select the iSCSI Initiator that is about to
do discovery.

ii.

Enable CHAP and enter a CHAP secret. For example:

CHAPsecret01

2.

Enable CHAP for the mpx100/100b iSCSI port:
• To enable CHAP for the mpx100/100b iSCSI port using the HP StorageWorks mpx Manager:

a.

Select the appropriate iSCSI port number.

b.

Click Advanced Configuration.

c.

Select the Enable CHAP check box.

d.

Enter a CHAP secret. For example:

hpstorageworks

• To enable CHAP for the mpx100/100b iSCSI port using the mpx100/100b CLI:

a.

Enter the set iscsi portnumber command.

b.

Select the Presented Target the initiator will log in to.

c.

Select the BiDi Discovery CHAP check box.

d.

Enter a CHAP secret. For example:

hpstorageworks

3.

Enable CHAP on the mpx100/100b iSCSI Presented Target.

a.

Click the General tab.

b.

Click Secret in the middle of the screen.

c.

Click Reset.

d.

Enter the mpx100/100b iSCSI Presented Target CHAP secret. For example:

hpstorageworks

e.

Click OK.

f.

Click Discovery.
• For manually discovering iSCSI target portals:

i.

Click Add under Target Portals.

ii.

Enter the IP address of the iSCSI port of the mpx100/100b.

EVA iSCSI Connectivity User Guide

217

Advertising
This manual is related to the following products: