Verifying configuration settings – HP 3000 Enterprise Virtual Array User Manual

Page 118

Advertising
background image

2.

Create a Solaris iSCSI host entry to present LUNs to an iSCSI host using HP Command View
EVA. Follow the procedure

Creating an iSCSI initiator host via HP Command View EVA

, page 128.

(Note that the host mode setting for Solaris is Linux/MAC.

3.

Enable the SendTargetsdiscovery method:

# iscsiadm modify discovery --sendtargets enable

4.

Create the iSCSI device links for the local system:

# devfsadm -i iscsi

Verifying configuration settings

To verify the configuration settings, display the LUNs configured to each path by executing iscsiadm
list target -S

:

NOTE:

The following example shows four paths (ports) visible from the array on the host and two LUNs
configured on the array for the host.

For example:

#

iscsiadm list target –S

Target:

iqn.1986-03.com.hp:fcgw.mpx100:mpx100-66.0.

50001fe150002f70.50001fe150002f78

Alias:

QlgcIsciTgtNode

TPGT:

0

ISID:

4000002a0000

Connections:

1

LUN:

3

Vendor:

HP

Product:

HSV210

OS Device Name:

/dev/rdsk/

c4t600508B400107271000060000C540000d0s2

LUN:

4

Vendor:

HP

Product:

HSV210

OS Device Name: /

dev/rdsk/

c4t600508B400107271000060000C540000d0s2

Target:

iqn.1986-03.com.hp:fcgw.mpx100:mpx100-66.0.

50001fe150002f70.50001fe150002f7a

Alias:

QlgcIsciTgtNode

TPGT:

0

ISID:

4000002a0000

Connections:

1

LUN:

3

Vendor:

HP

Product:

HSV210

OS Device Name:

/dev/rdsk/

c4t600508B400107271000060000C540000d0s2

Setting up the iSCSI Initiator for multipathing

118