Show fc command, Show initiators command, 162 show initiators command – HP 3000 Enterprise Virtual Array User Manual

Page 162

Advertising
background image

The following is an example of the show iscsi command:

iSCSI Port Information
------------------------
iSCSI Port

1

Port Status

Enabled

Link Status

Up

iSCSI Base Name

iqn.1986-03.com.hp:fcgw.mpx100:mpx100-74.0

MAC Address

00-c0-dd-0c-8d-c2

IP Address

33.33.66.73

Subnet Mask

255.255.0.0

Gateway IP Address

0.0.0.0

Firmware Revision No.

3.00.02.44

No. of Open Connections 0
Target TCP Port No.

3260

MTU Size

Jumbo

Window Size

32768

Window Scaling

Disabled

Current Port Speed

1Gb/FDX

Programmed Port Speed

Auto

Header Digests

Disabled

Data Digests

Disabled

Max Burst

262144

Max First Burst

65536

VLAN

Disabled

Examples

Show FC command

Displays FC port information for the specified port. If the port is not specified, both ports are displayed.

None

Authority

show fc [<port_num>]

Syntax

port_num

: The number of the FC port to be displayed.

Parameters

The following is an example of the show fc command:

mpx100 #> show fc 1
FC Port Information
---------------------
FC Port 1
Link Status Down
Current Link Rate Unknown
Programmed Link Rate Auto
WWNN

20:00:00:c0:dd:0c:60:11

WWPN

21:00:00:c0:dd:0c:60:11

Port ID

00-00-00

Firmware Revision No.

3.03.07

Frame Size

2048

Execution Throttle

64

Connection Mode

Unknown

Programmed Connection Option

Loop Preferred

Examples

Show Initiators command

Displays SCSI Initiator information for iSCSI and/or FC.

Command line interface

162

Advertising
This manual is related to the following products: