Rack mounting the mpx100/100b, Rack mount the mpx100/100b – HP 3000 Enterprise Virtual Array User Manual

Page 46

Advertising
background image

2.

Remove the orange Fibre Channel cable from the existing mpx100/100b FC2 port and Fibre
Channel switch port.

3.

Connect one end of the cable into the new mpx100/100b FC1 port and the other end into the
second Fibre Channel switch port.

4.

Disconnect the orange Fibre Channel cable from the top controller FP1 at the Fibre Channel
switch end and connect it to the second Fibre Channel switch port.

5.

Disconnect the orange Fibre Channel cable from the bottom controller FP2 at the Fibre Channel
switch end and connect it to the first Fibre Channel switch port.

6.

Continue with

Connect the mpx100/100b to an IP switch

” on page 47.

Rack mounting the mpx100/100b

WARNING!

Mount the mpx100/100b in the rack so that the weight is evenly distributed. An unevenly loaded
rack can become unstable, possibly resulting in equipment damage or personal injury.
This product is supplied with a three-wire cable and plug for the user's safety. Use this power cable
in a properly grounded outlet to avoid electrical shock. An electrical outlet that is not correctly wired
could place hazardous voltage on metal parts of the switch chassis. It is the responsibility of the
customer to ensure the outlet is correctly wired and grounded to prevent electrical shock.
If the chassis is installed in a closed or multi-rack assembly, the operating temperature of the rack
environment may be greater than the ambient temperature. Be sure to install the chassis in an
environment that is compatible with the maximum ambient rated temperature.

You will need one Phillips head screw driver. To rack mount the mpx100/100b:

NOTE:

The rear of the C-Shelf is the end without the knurled thumbscrews.

1.

Assemble two slide brackets (right and left) on the back ends of the C-Shelf, using the four hole
nut plates.

a.

Mount the C-Shelf with the open side up.

b.

Fit the slide bracket along the 1U side at the back of the C-Shelf with its screw hole tab
pointing outboard and its lip supporting the C-Shelf. There is a right-hand slide bracket and
a left-hand slide bracket.

c.

Place the nut plate outside the right-hand slide bracket with the dimpled threaded holes
pointing outboard.

d.

Place two screws (10-32 Pan 0.625 XRCS) through the two holes at the back of the C-Shelf,
through the slide plate slots, and loosely into the front two threaded holes of the nut plate.

e.

Repeat with the opposite hand slide bracket.

2.

Install the C-Shelf assembly into the rack.

a.

Locate a clear 1U area space within the rack.

Installing and upgrading EVA iSCSI connectivity

46