Scsi controller, Attributes, Logical – HP NonStop G-Series User Manual
Page 184: Actions, Responsive test, Scsi controller logical, Scsi controllers, Three

SCSI Controller
A controller that manages devices using the Small Computer System Interface (SCSI) protocol. This SCSI controller
is a component of Processor Multifunction (
) CRUs and I/O Multifunction (
) CRUs.
Location in OSM Tree: System > Group > Module > PMF2 > SCSI Controller
Slot Location: SCSI controllers are located on PMF CRUs in slots 50 and 55 of processor enclosures and on IOMF
CRUs in slots 50 and 55 of I/O enclosures.
Example: SCSI Controller (1.1.55.1)
Attributes
SCSI Controller
Displayed in the Attributes tab and Attributes dialog box only if the value is something
other than OK.
Service State
Logical
The ID to which the device answers on the SCSI bus:
4 or 5: Tape devices
6 or 7: Controllers
8 and 9: SCSI extenders/FC converters
The remaining IDs are for the device on the SCSI bus.
SCSI ID
The bus to which the device is attached:
Bus 1 or 2: Internal device
Bus 3: External device
SCSI Bus Number
Actions
Responsive Test
Verifies that the component is installed and responding.
184
System Resources