Clearing the hardware compression faults – HP StorageWorks 6000 Virtual Library System User Manual

Page 196

Advertising
background image

•

Test type — Background or Read-only

•

Storage pools — All or the number of the storage pool tested

•

Test start time

•

Test end time

•

Current job count

•

Total job count

•

Total amount of data written during the test

•

Total amount of data read during the test

•

Total number of successful jobs

•

Total number of failed jobs

•

Status of the test

Decompression errors will be logged once per occurrence. The data fields are in order as follows.
See “

Log Monitor Summary

” on page 195 for descriptions not defined here:

•

Decompression_error — indicates that this row of data is the decompression information.

•

Decompression error ID

•

Time the error occurred

•

sDev Number

•

LBA

•

Offset

•

Length

•

UUID

Jobs are only logged in event of a job failure. The data fields are in order as follows:

•

Job — indicates that this row of data is the job information

•

Job ID

•

Date of the test

•

Generated job key

•

Test start time

•

Time of last update to the job

•

Test end time

•

Number of the storage pool tested

•

Total amount of data written during the test at this point

•

Direction — read or write

•

Result — success or fail

•

Message, if any, associated with the failed job

•

External connect error, if any

•

Source barcode of the job

•

Target barcode of the job

Clearing the Hardware Compression Faults

If the VLS node is showing a hardware compression status that you think is incorrect, or if you want
to verify the status shown, you can force a rescan of the node.

From Command View VLS:

1.

On the System tab, expand Chassis in the navigation tree.

Monitoring

196

Advertising