HP StorageWorks 6000 Virtual Library System User Manual

Page 248

Advertising
background image

Action

Status

Description

Item

One or more components have experienced an elev-
ated temperature or a thermal shutdown.
A thermal shutdown is indicated by the Therm Trip
LED.

•

Be sure the processor heatsink is properly attached.

•

Be sure there are no 1.7" DIMMs installed that
prevent airflow across the processor heatsink).

•

Be sure that all fans are installed and working
properly.

•

Be sure that the node environment meets posted
requirements.

For information about node environment requirements
refer to the “Optimum environment” section in Chapter
3.

Off = Normal
On = Attention
required

Temperature

5

DIMM failure or configuration error. Refer to the IML
or POST messages

Off = Normal
On = Attention
required

DIMM

6

A power fault on the system I/O board occurred. If
problem persists, replace the system I/O board.

Off = Normal
On = Attention
required

I/O power fault

7

The node experienced a thermal shutdown.
If one of the CPU thermal LEDs is amber, that CPU
experienced an overtemperature condition.

•

Be sure that the processor heatsink is properly at-
tached. For more information, refer to the mainten-
ance and service guide.

•

Be sure the correct DIMMs (1.2" tall) are installed.

•

Be sure all fans are installed and working properly

For more information, refer to the maintenance and
service guide.

Off = Normal
On = Attention
required

Therm trip

8

Ensure the SCSI backplane is installed properly.
Reseat SCSI backplane board and hard drives.

Off = Normal
On = Attention
required

SCSI interlock

9

Look at the LEDs on the front of the power supply and
take the appropriate action.

Off = Normal
On = Attention
required

Power supply 1

10

Look at the LEDs on the front of the power supply and
take the appropriate action.

Off = Normal
On = Attention
required

Power supply 2

11

Component Identification

248