Quickfind diagnostic display leds – HP StorageWorks 6000 Virtual Library System User Manual
Page 247

QuickFind Diagnostic Display LEDs
The QuickFind Diagnostic Display is located on the top of the access panel and displays the node
internal component and temperature status.
Action
Status
Description
Item
Be sure fan is installed and seated properly.
If fan is installed and seated properly, replace the fan.
Off = Normal
On = Attention
required
Fan
1
Processor pre-failure notification. Inspect the IML logs
and POST messages.
Processor might need to be replaced.
Off = Normal
On = Attention
required
Processor
2
Processor memory board power failure.
If problem persists, replace the processor or processor
memory board.
Off = Normal
On = Attention
required
Processor memory
board
3
PPM power failure. If problem persists, replace PPM.
If the PPM and the BRD LEDs are both on, there is a
configuration error.
Off = Normal
On = Attention
required
Processor power
module
4
HP StorageWorks 6000–series Virtual Library System User Guide
247