Snmp generated trap definitions – HP Integrated Lights-Out 2 User Manual

Page 66

Advertising
background image

SNMP Pass-thru

p-Class Alert Forwarding (displayed on p-Class servers only)

For more information see to the HP Integrated Lights-Out Management Processor Scripting and
Command Line Resource Guide
at

http://h20000.www2.hp.com/bizsupport/TechSupport/

DocumentIndex.jsp?contentType=SupportManual&lang=en&cc=us&docIndexId=64179&
taskId=135&prodTypeId=18964&prodSeriesId=1146658

.

To configure alerts:

1.

Log in to iLO 2 using an account that has the Configure iLO 2 Settings privilege.

2.

Select Management in the Administration tab. The SNMP/Insight Manager Settings screen
appears.

3.

In the SNMP Alert Destination(s) fields, enter up to three IP addresses that you want to receive
the SNMP alerts and select the alert options you want iLO 2 to support.

4.

Click Apply Settings.

Test alerts include an Insight Manager SNMP trap and are used to verify the network connectivity
of iLO 2 in HP SIM. Only users with the Configure iLO 2 Settings privilege can send test alerts.

Be sure you have saved any changes to the SNMP Alert Destination(s) fields before sending a test
alert.

To send a test alert:

1.

Select Management in the Administration tab. The SNMP/Insight Manager Settings screen
appears.

2.

Click Send Test Alert in the Configure and Test SNMP Alerts section to generate a test alert
and send it to the TCP/IP addresses saved in the SNMP Alert Destinations fields.

3.

After generating the alert, a confirmation screen appears.

4.

Check the HP SIM console for receipt of the trap.

SNMP generated trap definitions

You can generate the following SNMP traps on BL c-Class servers and iLO 2:

ALERT_TEST

– Verifies that the SNMP configuration, client SNMP console, and network are

operating correctly. You can use the iLO 2 interface to generate this alert to verify receipt of
the alert at the SNMP console. You can also generate this alert using the iLO 2 Option ROM
to verify SNMP configuration settings.

ALERT_SERVER_POWER

– Occurs when the iLO 2 management processor detects an

unexpected transition of the host system power, either from ON to OFF, or OFF to ON.

66

Configuring iLO 2