9 common performance table columns, Common performance table columns – HP 3PAR System Reporter Software User Manual

Page 322

Advertising
background image

10.30

The Sample Data and Inventory Tables

3PAR System Reporter User’s Guide

System Reporter 2.8

10.4.9 Common Performance Table Columns

The statport, statvlun, statld and statpd tables all have a common set of columns for the

performance data. These columns are described in

Table 10-19

.

Table 10-19. Common Performance Columns

Column

Type

Comment

begin

DOUBLE PRECISION NOT

NULL

Timestamp value indicating when the

counting started (typically when the system

was rebooted or the device was created).

Two count samples should only be

compared if the begin value is the same for

the two samples. For example, the

difference between rcount values of two

samples represents the number of read

operations in the interval between those

samples only if the begin values are the

same for those samples.

d_begin

DOUBLE PRECISION NOT

NULL

Difference between begin value from last

sample for the same object.

now

DOUBLE PRECISION NOT

NULL

Timestamp value in microseconds. The

difference in the now values of two

samples should be used in calculating the

time interval between two samples

d_now

DOUBLE PRECISION NOT

NULL

Difference between now value from last

sample for the same object.

qlen

DOUBLE PRECISION NOT

NULL

Queue length at the time of the sample.

qlen is an instantaneous measure, not an

average queue length over the sample

period.

qlen may not be available for all objects

and its value will be negative to indicate

that it is invalid.