HP StorageWorks 2.64 Director Switch User Manual

Page 85

Advertising
background image

Director Element Manager user guide

85

• G Port Module—For the fiber channel port card, the following acronyms may display to

indicate the card’s port technology:
• GLSL—G_Port, long wave, single mode LC connector, 1 Gigabit
• GSML—G_Port, short wave, multimode, LC connector, 1 Gigabit
• GXXL—G_Port, mixed mode, LC connector, 1 Gigabit
• FPM—G_Port, small form factor pluggable (SFP) optics, fibre port module, 1 Gigabit
• UPM—G_Port, small form factor pluggable (SFP) optics, universal port module, 2

Gigabit

• GSFM—G_Port, short wave, small form factor, multimode, 1 Gigabit
• GLSR—G_Port, short wave, single mode, MT-RJ connector, 1 Gigabit
• GXXR—G_Port, mixed mode, MT-RJ connector, 1 Gigabit
• GXXL—G_Port, mixed mode, LC connector, 1 Gigabit

• Cooling FAN—Fan module.
• PWR—Power supply module.

•

Position—A number representing the FRU chassis position. The chassis (slot) position for a

nonredundant FRU is 0. The chassis positions for redundant FRUs are 0 and 1. For the Director

2/64 chassis, port positions are 0–63. For the Director 2/140 model, port positions are

0–127 and 132–143. Note that for the Director 2/140, ports 128–131 are internal ports and

are not available for external connections.

•

Status—The FRU status (Active or Backup).

•

Part Number—The FRU part number.

•

Serial Number—The FRU serial number.

To display the FRU Properties dialog box for an FRU:

•

Click the FRU’s row and select Product > FRU > FRU Properties.
Or

•

Double-click an FRU.

Advertising
This manual is related to the following products: