Table 40 Error Code and Error Contents When Operating RAID Manager (continued)

Error Contents

Error Code (SSB2)

Error Code (SSB1)

1.

The S-VOL was a pool volume for XP Snapshot.

2.

The S-VOL was the S-VOL of an XP Snapshot pair or a V-VOL for
XP Snapshot.

3.

The S-VOL was the P-VOL of an XP Snapshot pair and one of the
following conditions held true:
• The XP Snapshot pair was being restored.
• The XP Business Copy quick restore operation was performed.
• The create pair operation was performed on the XP Business

Copy pair.

Because the specified P-VOL was a P-VOL for an XP Continuous Access
Journal pair for a delta resync operation, one of the following errors
occurred:

2078

1.

Because the XP Continuous Access Journal pair was not in the PSUS
status, the reverse copy operation was rejected.

2.

The quick restore operation was rejected.

Because the specified P-VOL was a P-VOL for an XP Continuous Access
Journal pair for a delta resync operation, the pair operation was
rejected.

2079

Because the initialization process was being performed, the pair
operation was rejected.

2086

Because the volume specified as a P-VOL was undergoing Quick
Format, the Quick Restore operation was rejected.

2089

Because the volume specified as an S-VOL was undergoing Quick
Format, the Quick Restore operation was rejected.

208a

Because the volume specified as the S-VOL was a FICON Data
Migration volume, the pair operation was rejected.

208c

The volume specified as a P-VOL was an S-VOL of an XP Continuous
Access asynchronous pair. Because the status of the XP Continuous

2093

Access asynchronous pair was not Suspend, the Split operation was
rejected.

The volume specified as a P-VOL was an S-VOL of an XP Continuous
Access asynchronous pair. Because the consistency time of the

2094

b9a0/b9a1/b9a2/

b9a5/b9a6/b9ae/

consistency group is not equal to the consistency time of the XP
Continuous Access asynchronous pair, the Split operation was rejected.

b9af

When you performed the quick restore command, the quick restore
operation was rejected because of one of the following reasons:

2097

The P-VOL of the XP Business Copy pair was an XP Thin Provisioning
V-VOL and the S-VOL of the XP Business Copy pair was a normal
volume.

The P-VOL of the XP Business Copy pair was a normal volume and
the S-VOL of the XP Business Copy pair was an XP Thin Provisioning
V-VOL.

Because the emulation type of only one of volumes in the XP Business
Copy pair was OPEN-0V, the quick restore operation was rejected.

209b

Because the updated information about system configuration was being
backed up, the quick restore operation on the volume was rejected.

209c

Because the volume specified as the P-VOL was a FICON Data
Migration volume, the pair operation was rejected.

209e

Troubleshooting When Using RAID Manager