background image

Hardware options installation 13

IMPORTANT:

Before removing any serviceable parts, determine whether the part is hot plug or

non-hot plug. If the device is non-hot plug, you must power down the server. Non-hot plug devices

in the server include the processor, all boards, memory modules, fan, expansion boards, and all
system drives.

IMPORTANT:

Review the specifications of a new component before installing it to verify that it is

compatible with the server. When you integrate new components into the system, record the

model number, serial number, and any other pertinent information for future reference. After

completing any removal or replacement procedure, run the diagnostics program to verify that all

components operate properly.

HP MicroServer Remote Access Card

The operating system has the BMC Setup function when the IPMI card is installed into the server. By BIOS

default, the server exports the VGA port through the VGA connector on the IPMI card automatically when the

IPMI card is plugged. You can use the RJ45 port (LAN port) on the IPMI card to connect the WebUI of BMC.

Resetting the MicroServer Remote Access Card password to
default

You can use the IPMI tool via KCS to reset the administrator password to "password."
Use the following Linux ipmitool command:

ipmitool raw 18 47 82 2 0x70 0x61 0x73 0x73 0x77 0x6f 0x72 0x64 0x00 0x00

0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00